Ingrid Ullmann, Julian Adametz, Daniel Oppelt, Andreas Benedikter, and Martin Vossiek
Institute of Microwaves and Photonics, Friedrich-Alexander University, Erlangen, 91058, Germany
Received: 29 Sep 2017
–
Revised: 31 Jan 2018
–
Accepted: 21 Mar 2018
–
Published: 20 Apr 2018
Abstract.Purse N 034 Teal Green And Bag Clutch Evening Carlo Kathleen Beaded Style Fellini Sequined q4w1SpU Millimetre-wave (mmW) imaging is an emerging technique for non-destructive testing. Since many polymers are transparent in this frequency range, mmW imaging is an attractive means in the testing of polymer devices, and images of relatively high resolution are possible. This contribution presents an algorithm for the precise imaging of arbitrarily shaped dielectric objects. The reconstruction algorithm is capable of automatically detecting the object's contour, followed by a material-sensitive reconstruction of the object's interior. As an example we examined a polyethylene device with simulated material defects, which could be depicted precisely.
Citation: Ullmann, I., Adametz, J., Oppelt, D., Benedikter, A., and Vossiek, M.: Non-destructive testing of arbitrarily shaped refractive objects with millimetre-wave synthetic aperture radar imaging, J. Sens. Sens. Syst., 7, 309-317, https://doi.org/10.5194/jsss-7-309-2018, 2018.